HAI-P200-4G · Remote maintenance & monitoring

Monitor your machines and intervene remotely. From day one.

One box between your PLCs and your desk: multi-protocol acquisition, local historisation, automatic charts, alerts that arrive with their context, and built-in Tailscale remote access. No development, no licence, no IT ticket.

Installed in under an hour Zero lines of code Read-only acquisition 4G + Tailscale built in
HAI-P200-4G industrial gateway
Why swap your standard modem

Three frictions that stall monitoring projects

The VPN headache

Traditional industrial VPNs need firewall rules, a public IP, a server to maintain — and they lock you into one vendor.

Alarms with no context

A fault fires, and someone has to reconstruct what happened before it: phone calls, exports, spreadsheets. Time goes into investigating, not repairing.

The IT barrier

Custom scripts, config files edited by hand, dashboards built by hand: monitoring should no longer require developer skills.

Connect · Visualise · Notify

Three steps, and your fleet is under watch

Days of configuration turned into minutes of installation.

Hover or click a band to see the real interface

Step 01

Connect without coding

The Data-Plug graphical configurator declares your devices and variables in a few clicks: address, slave ID, polling rate, data type, byte order, unit, scale. No file to edit, no script.

  • Modbus TCP, serial Modbus (RS232/RS485), S7, OPC-UA with a built-in node browser
  • Categorise on the spot: measure, state, counter, alarm
  • Read-only acquisition: the box never writes into your PLCs
  • CSV import / export: 500 points in a spreadsheet instead of 500 clicks
Data-Plug — inputs configuration
Data-Plug interface: Modbus input configuration
Step 02

Visualise instantly

No dashboard to build: the Data-Explorer adapts to the variables you declared and picks the right rendering on its own.

  • Real-time Live mode, or history with two-period comparison
  • Smooth curves for measurements, step charts for states, bars for counters
  • Production batches: one click opens the history locked on the batch window
  • GPS / NMEA position on a map, read-only guest access for your customer
Data-Explorer — measures, states, counters
Data-Explorer: measurement curve, step chart and counter bars
Step 03

Notify, escalate, acknowledge

Alarms and reports share the same output channels. For an alarm you choose: a direct send, or an escalation chain you compose — your levels, your retries, your recipients.

Alarm

Rising edge, with debounce

Direct notification

One immediate send to the alarm recipients

Or an escalation you compose

Your levels, your retries, your recipients — up to a voice call as last resort

Output channels
✉️ E-mail💬 SMS ✓📞 Call ✓🔗 Webhook
✓ Acknowledging — reply “OK” or press 1 during the call — stops the escalation.
Report

Daily, weekly or on batch closure

straight through
The alert e-mail you receive

What the e-mail carries

  • Alarm name, severity, timestamp and the controller involved
  • The measurements that deviated most from their usual behaviour, with their value at trigger time
  • Trend charts for the top three and the alarm state, rendered inside the mail
Alert e-mail with the top impacted variables
Industrial connectivity

The acquisition protocols

Six inputs configured from the same web interface, with no intermediate gateway — and always read-only.

Modbus
Modbus TCP Production

Holding & input registers, coils, discrete inputs. 17 data types, 16/32/64-bit byte order, scale and unit per variable.

Modbus RTU
Modbus RTU Production

RS232 / RS485 on the four terminal-block ports through the built-in RTU→TCP gateway. 1200 to 115200 baud, 8N1 by default.

Siemens S7
S7 · ISO-on-TCP Production

Reads data blocks on S7-300/400/1200/1500. On 1200/1500: PUT/GET enabled and non-optimised DB access required.

OPC UA
OPC-UA Production

Built-in node browser; anonymous, username or certificate auth, with client certificate generation from the interface.

BACnet
BACnet/IP

Who-Is discovery and network scanning; reads analog, binary and multi-state objects (present-value).

NMEA
NMEA 0183

TCP client, TCP server or UDP, with talker filtering. Listen mode shows the live stream; one click turns a field into a variable.

MQTT
Internal MQTT Via Node-RED

Anything a Node-RED flow can read becomes a historised variable: external APIs, exotic sensors, in-house formats.

Out to your systems

Outbound MQTT and HTTPS JSON webhooks with bearer tokens: your data reaches your SaaS, SCADA or ERP, with failed messages replayed.

PLCs & platforms connected

Siemens Schneider Electric Wago Beckhoff Rockwell / Allen-Bradley Omron Mitsubishi ABB Phoenix Contact Delta Johnson Controls Isma Controlli CODESYS and many more

Nothing in the box is vendor-specific: any device that speaks Modbus, S7, OPC-UA, BACnet/IP or NMEA 0183 connects. And we program these platforms daily — it has been our core business from day one.

Remote maintenance

Your PLCs, from your desk. Without an IT ticket.

The HAI-P200-4G embeds Tailscale, a modern WireGuard-based VPN: one encrypted outbound connection, no public IP, no inbound rule to request.

  • Commissioned with an auth key pasted into the web interface: two minutes, no VPN server to install.
  • Subnet advertised in CIDR: the machine's whole local network becomes reachable, including devices that know nothing about VPNs.
  • Or port by port, when IT refuses to have its LAN routed: targeted forwarding of one port to one device.
  • Diagnose with your own tools: CODESYS, TIA Portal, a browser, VNC — addressing the device by its IP.
WireGuard No inbound port Works behind 4G No routing between interfaces by default
Diagram: user PC, Tailscale tunnel over the Internet, HAI-P200-4G gateway, PLC on the local network
An encrypted tunnel from the engineer's laptop to the PLC, with no public IP and no port forwarding. Devices are addressed by IP: broadcast-based discovery (PROFINET DCP, CODESYS scan) does not cross the tunnel.

Even without a VPN

The box polls your server outbound; you answer with a command. Update, reboot, system snapshot — straight through 4G, without a single inbound port.

Redundant Internet link

Automatic failover Ethernet → Wi-Fi → 4G, continuously probed. The site stays reachable even when the plant network goes down.

Commissioning from a phone

Turn on the Wi-Fi hotspot and its captive portal: set the box up from a smartphone, QR code included, with no laptop or patch cable in the cabinet.

Updates under control

Signed software repository, version of your choice, rollback available. You decide when a machine changes version.

Monitoring

From a PLC variable to a PDF report

The whole chain runs inside the box. No mandatory cloud, no platform subscription.

01 — ACQUISITION

We read your devices

Cyclic polling per device, adjustable rate (5 s by default). Unit, description and category are carried by the variable.

02 — HISTORISATION

We store it locally

Embedded database on the box, partitioned by month, 30-day retention by default. History stays available without Internet; the industrial micro-SD extends capacity.

03 — BATCHES

We split by production batch

You designate the variable that identifies the batch: its transitions open and close batches automatically. One click reopens the history on the exact batch window.

04 — REPORTS

We send the summary

Daily, weekly, or on batch closure: the e-mail carries the summary — statistics for your favourite variables, charts for the first five, CSV optional — and the same report is generated as a PDF, archived and readable from the interface.

📄

The batch closes, the report leaves on its own. For a production shop, that is traceability nobody has to remember.

Diagnostic assistance

When the alarm lands, you already know where to look.

On every alarm the box compares the last 30 minutes of each measurement against its usual behaviour, and attaches the five that deviated most — with trend charts for the top three. The operator opens the mail and sees where to look instead of reconstructing the context afterwards.

Honestly: this is a statistical deviation analysis (z-score), not an oracle. It points at temporal correlations — what it saves is diagnosis time, not the cause it asserts.

30-minute analysis window: variables ranked by impact with their trends
Built into the interface: impact per variable, value at alarm time, and trends over the analysed window.
On-call

A gateway that calls you at 3 a.m.

Most gateways send an e-mail and consider the job done.

What happens when an alarm fires

Alarm NiveauHaut HAI-P200-4G · Line 2
✉️ E-mailwith the charts
💬 SMSreply “OK”
📞 Voice callpress 1 to acknowledge

Alarm fired — level 1 notified immediately.

No acknowledgement — moving to the next level.

Acknowledged during the call — the chain stops.

Automatic voice call

As a last resort the box calls and reads out the alarm with speech synthesis. Press 1 during the call to acknowledge. A voice-enabled SIM is required.

Escalation by levels

Level 1, retry, level 2: channels are chosen per person and per level. The chain stops at the first acknowledgement — SMS "OK", a keypad press, or the interface.

Anti-flood by design

Minimum active time, cooldown between two sends, cap per time window. A chattering alarm does not wake the on-call engineer twenty times.

Ecosystem

Simple by default does not mean limited

An application catalogue installs on the box in one click, with volume backup and restore.

Node-RED Grafana Ignition Edge PostgreSQL pgAdmin Modbus RTU → TCP gateway

Guest access

Open a few read-only pages to your end customer — plus a link to their Grafana or Node-RED — without ever handing over administration.

Custom flows

Node-RED stays the universal escape hatch: external APIs, proprietary formats, business calculations. What it produces comes back as an ordinary historised variable.

Accessible interface

Contrast, text size, keyboard navigation, reduced motion: the interface meets the accessibility requirements of public tenders.

Hardware

Built to last. In the cabinet, anywhere.

HAI-P200-4G aluminium DIN-rail enclosure with 4G antenna

Core & power

Module
Raspberry Pi CM4
Quad-core · 4 GB RAM
Storage
32 GB soldered eMMC
+ optional 128 GB industrial micro-SD — historisation moves to it automatically
System
Debian 12 · HAI-OS
Web admin interface

Connectivity

Wired network
Two Ethernet ports
Configured separately, no routing between them by default
Serial ports
4 on the terminal block
2× RS232 + 2× RS485
Wireless & remote
4G LTE + Wi-Fi
Tailscale built in, automatic link failover

Ruggedness

Form factor
Aluminium enclosure
DIN-rail mounting
Power
Industrial terminal block
Wide DC range
Reliability
Real-time clock
Service supervision with automatic restart
Use cases

Who puts a HAI-P200 in the cabinet

Machine builders · OEM

Monitor the installed base without blowing up service costs

The same box on every machine shipped: instant remote access, history ready when the customer calls, and a recurring service offer to sell.

Production shops

One report per batch, with nobody remembering

The batch closes and the PDF leaves with its statistics and charts. Traceability by configuration, not by development.

BMS / HVAC — with Scorp-IO

The field layer of a SaaS platform

Instrumented air handling units (temperature, CO₂, humidity) with data fed cleanly into the vendor's platform.

Marine & inland waterways

Mobile sites that sync when coverage returns

NMEA 0183 over TCP or UDP, position on a map, and local historisation that absorbs the dead zones: edge before cloud.

FAQ

What people ask before ordering

Can the box write into my PLC?+

No, by design: acquisition is strictly read-only. No command is ever sent to your equipment, which makes the conversation with your security team far shorter.

Do we have to modify the PLC program?+

In most cases, no: we read the variables already exposed (Modbus registers, S7 data blocks, OPC-UA nodes). On S7-1200/1500 you simply enable PUT/GET and turn off optimised access on the blocks being read.

Does my data leave for the cloud?+

No. Acquisition, historisation and visualisation run inside the box. You then decide what to republish, and to whom, over MQTT or a webhook.

What happens during a network outage?+

Collection carries on: historisation is local and does not depend on Internet. Untransmitted data is replayed on reconnection, within the configured retention (30 days by default).

Will our IT department have to open ports?+

No. Everything goes out as an encrypted outbound connection: no public IP, no port forwarding, no inbound rule. With 4G the box can stay entirely off the corporate network.

How are alarms triggered?+

On the state change of a boolean variable declared as an alarm — thresholds stay in your PLC, where they belong. The box adds debounce, escalation, acknowledgement and diagnostic context.

Next step

Ready to connect your installations?

One test unit for next week, or a fleet for the year? Describe your need and we come back with a full quote — box, antennas, storage, power supply and the right options.

No salespeople: you talk directly to the engineer who will handle your project.